The reverse osmosis water treatment equipment is divided into two parts. One part is pre-treatment debugging, and the other part is the reverse osmosis host debugging. The pre-treatment mainly involves washing quartz sand and activated carbon in both positive and negative directions to wash away fine sand and impurities, control the amount of incoming water, and adjust the flow and pressure of incoming and outgoing water. Jinzong Enterprise, which has more than 20 years of experience in water treatment equipment production and development, has summarized the following points for everyone:


1. Analyze and test the inlet water of the device, and the results show that it meets the inlet water requirements before proceeding with water commissioning of the device.


2. Adjust the pressure control system of the high-pressure pump.


3. Check whether the connections between all pipelines of the device are complete, whether the pressure gauge is complete, whether the low-pressure pipeline connections are tight, and whether there is a shortage.


4. Fully open the pressure gauge switch, main inlet valve, concentrated water discharge valve, and produced water discharge valve.


5. Start the pre-treatment equipment and adjust the water supply to be greater than the total water intake of the device.


6. Backwash and wash the sand and charcoal filter until the water is clear.


7. Start the high-pressure pump and slowly open the main inlet valve of the device. Control the total inlet pressure of the device to be less than 0.5Mpa, flush for 5 minutes, and check whether all high and low pressure pipelines and instruments are normal.


8. Adjust the inlet valve and concentrated water discharge valve to achieve an inlet pressure of 1.0-1.4 Mpa.


9. Detect the conductivity of the product water, and when it meets the requirements, open the product water outlet valve and close the produced water discharge valve.


10. The debugging of the RO device is all manual single step operation. After normal operation, it can be switched to automatic mode, which is automatically controlled by online instruments and PLC.


11. Start the regeneration system and check if it is working properly.

The most important thing to pay attention to during reverse osmosis debugging is to remember to close the outlet valve and open the high-pressure pump, as this can cause significant damage. Therefore, during debugging, it is necessary to pay attention to whether the pipeline is in the same path before starting the water pump.


Previous: Discussion on Key Points of Quality Management in Pharmaceutical Water Systems
Next: How to purchase a suitable stainless steel reactor?

PRODUCT CENTER

SOLUTION

Vacuum Emulsify Machine

Custom Reactor

Dispersion Machine

Sanding Machine

Mixing Machine

Filling Machine

Cream emulsion machine

Stainless steel storage tank

Water treatment machine

Primary fermentation equipment

Automatic production system


Cosmetics production equipment

Cream production equipment

Liquid production equipment

perfume production equipment

Lipstick production equipment

Fog tank production line equipment

Powder production line equipment

Toothpaste production line equipment

Soap production line equipment

Chemical production equipment

Alkyd resin production line equipment

Acrylic resin production line equipment

PU polyurethane production line equipment

Epoxy resin production line equipment

Polyol production line equipment

Silicone oil production line equipment

Hot melt adhesive production line equipment

Modified rosin resin production line equipment

Adhesive production line equipment

Water reducing agent production line equipment

LED raw material mixing production line equipment

Water based acrylic acid production line equipment

Water based PU resin production line equipment

Paint production equipment

Oil paint production line equipment

Ink production line equipment

New Energy materials production equipment

Lubricating oil production line equipment

Vehicle fuel tank production line equipment

Food additive production equipment

Pharmaceutical equipment

Ointment production line equipment

Syrup production line equipment

Injection and potion production line equipment

Internet application

Contact Us


Tel86-20-39900130
Headquarters Add: Tian An HI-tech Ecological Park, Panyu Dist., Guangzhou City, China
Factory Add:NO.3, Kangtai Street, Zhaoqing National High-tech Zone(Dawang),Guangdong Province
Tel: 86-758-3623881

  • Official WeChat
  • official Weibo